Check each interface to see if there is communication with the indoor unit and master controller by looking at the two acknowledgement LEDs a. 2 termination resistors (typically 120 ohms) are required at the start and end of the communication bus. Wire all interfaces to the master controller following the BACnet or Modbus communication wiring protocols. Refer to Appendix section (page 11) for additional information on dip switch positions.
#HOW TO SWITCH ABAQUS 6.13 SERVER ADDRESS FOR CLIENTS MAC#
When ALL dip switches 1 5 are set to the ON position, the BMS system sees the device MAC address that is set in the software. After all interfaces have been configured, power down the system and set the dip switches accordingly to site requirements. You will see the Right LED (RS-485 ACK) light blink when clicking the Write Settings button.

Click the button Write Settings in the lower right hand corner after all the settings have been entered correctly. Enter the settings for each interface into the BACnet Settings window provided by the third party building/home automation system contractor.

Verify computer USB COM port is correct 12. Verify dip switches are set correctly ii. If unable to connect to the BACnet & Modbus Interface device, look back at the previous steps. Figure 6 is the BACnet Settings window that will open when connected to the BACnet & Modbus Interface device. After the correct COM port number has been selected, click the button Connect.
#HOW TO SWITCH ABAQUS 6.13 SERVER ADDRESS FOR CLIENTS SOFTWARE#
To change COM Port settings, refer to step 2 in the Software Tool Additional Configuration section (page 7). Note: Recommended COM Port setting for the Software tool is COM 1-9. Figure To find what COM port number the computer assigned the USB adapter refer to step 1 in the Software Tool Additional Configuration section (page 6). Figure 4 is the window that opens up when opening the software tool. Open the MelcoBEMS MINI (A1M) Configure Manager software by using the shortcut created on the desktop. Make sure USB to RS-485 adapter is plugged into USB COM port of the computer that has the MelcoBEMS MINI (A1M) Configure Manager software tool before powering up the system QSG of 17 v1.5.0ģ 8. Wire the USB to RS-485 adapter (Figure 2) (+) and (-) terminals to the BACnet & Modbus Interface terminal block respected terminals together with 120 ohm termination resistors at each end. If there are more than one interfaces, continue to plug in the remaining interface devices into the CN105 on the PCB of a powered off Mitsubishi Electric unit. Connect the BACnet & Modbus Interface device to connector CN105 on the PCB of the powered off Mitsubishi Electric unit that will be integrated. Figure 1 shows the correct dip switch position for this step. Make sure dip switches 1, 6, and 7 are ON and the remaining dips switches are OFF when trying to connect to the configuration tool software. Before configuring the BACnet & Modbus Interface device, the third party building/home automation system contractor needs to supply the MAC address, device instance number, baud rate and any other network settings needed for the RS-485 communication network. Ensure the power is turned off for the Mitsubishi Electric outdoor and indoor units of the system that will be integrated.
#HOW TO SWITCH ABAQUS 6.13 SERVER ADDRESS FOR CLIENTS INSTALL#
Download software from under the PAC-UKPRC001-CN-1 support page software section a Install the MelcoBEMS MINI (A1M) Configure Manager software tool a.